Non-Insulated Terminals

Product categories of Non-Insulated Terminals, we are specialized manufacturers from China, Non-Insulated Terminals, Non-Standard Copper Terminals suppliers/factory, wholesale high-quality products of Copper Wire Terminals R & D and manufacturing, we have the perfect after-sales service and technical support. Look forward to your cooperation!
China Non-Insulated Terminals Suppliers
Insulation terminal is low temperature suppress joint on the wire, cable or electrical equipment.There are many kinds of insulation terminal name, Insulated Terminals is also known as Cold-Press Terminal, air connector, etc.It is used to implement a accessories, electrical connection in the industry we will insulation terminal is classified into the category of the connector.We may be unfamiliar with insulation terminal, but when it comes to the connector, that we should be more familiar with.So in daily life we what to need to pay attention to in the use of the insulation of the terminals have to know?The dragon overflow terminal is to introduce the insulation terminal use matters needing attention.
A, should fully understand to the insulation of the terminal operation, familiar with the operation method, so as to ensure the correct operation;For the insulation of the terminal does not have the wrong operation, should use color code or markup to be identifiers, or right in front of the connection types are corresponding, and ensure the mutual connection correct positioning;Should pay special attention to prevent error with needle socket inserted, otherwise will damage the insulation terminal, and lead to accidental electrical contact;Should ensure that the insulation terminal connection in place, on special occasions is not easy to check, should be in the corresponding procedures to make detailed rules, and we can check through the looking glass.
Second, insulated terminal termination, shall be in strict accordance with the corresponding termination requirements specification or termination and check, and according to the corresponding node number termination.Selection of cable wires between the insulating layer thickness should be matching with contact element spacing, the cable core should have contact with a terminal matching, when exposed to a cross between, and lines.
Three, welding should according to the bare wire diameter to select the corresponding power electric welding each contact time is generally not more than 5 s, don't let the flux into the insulator should be paid attention to, lest cause the loss of product insulation resistance.
Four, insulated terminal is in a state of separation should be fitted with a protective cap or shall adopt other measures for dust;If the insulation terminal connection are not isolated, for a long time to be able to play on insurance between plug and socket.
Five, cleaning insulation terminal, the silk with anhydrous ethanol can be used for, dry after use.May cause harmful effects in the connector are not allowed to be used in the chemical solvents such as acetone.
Six, insulated terminal connection or separation, should try to make the plug and socket axis line, and the anchorage cable, avoid the plug role by tangential force, prevent cable sagging cause the damage of the connector.
Seven, insulated terminal before is not properly connected or completely lock, ban on electricity.
Eight, fixed in insulation terminals, wiring harness, clamping and so on occasion, use should be threaded connection locking device (locking screw, locking ring, fuse, etc.).
Nine, acceptance and testing insulation terminal, should according to the product related standards and requirements of the specification.Acceptance and inspection has been used by the electric connector, product related standards and operating instructions should be reduce the requirements, on the basis of the use of equipment insulation terminal should be intact, performance qualified;Probe should conform to the requirements of the standard, otherwise easy to jack damage.